Hot
Back to products
LEAF 67.2V 6A EV Charger for 60V Lithium-Ion Electric Scooter Battery
₹2,499.00 Original price was: ₹2,499.00.₹2,150.00Current price is: ₹2,150.00.
DALY 19S 60A LiFePO₄ BMS for 60V LFP Battery with NTC
₹2,499.00
The DALY 19S 60A LiFePO₄ BMS is designed for 60V-class lithium iron phosphate battery packs used in electric scooters, EVs, solar storage, inverter batteries and custom LFP systems.
Key Features
- 19S LiFePO₄ / LFP configuration
- 60.8V nominal battery voltage
- DALY marked 19S60V60A
- 60A discharge current
- 60A charge current
- Common-port / same-port design
- Individual cell-voltage monitoring
- Built-in cell balancing
- NTC temperature sensor
- Overcharge & over-discharge protection
- Over-current protection
- Short-circuit protection
- B- and P- high-current terminals
- Suitable for EV, inverter, solar ESS, UPS and custom LiFePO₄ battery packs
Important: This BMS is intended specifically for 19S LiFePO₄ battery packs. Battery chemistry, series count and current requirement must match before installation.
1 in stock
SKU:
66-19s-60A
Category: Battery Components & BMS
Tags: Battery Components And BMS, BMS for lithium Battery Pack
The DALY 19S 60A LiFePO₄ BMS is a Battery Management System designed for 19-series lithium iron phosphate battery packs.
The unit is marked:
- Brand: DALY
- Battery Chemistry: LiFePO₄
- Configuration: 19S
- Label Rating: 19S60V60A
- Charge Current: 60A
- Discharge Current: 60A
- Temperature Monitoring: NTC
- Main Connections: B- and P-
- BMS Type: Common-port hardware BMS
The BMS monitors the battery pack during charging and discharging and helps protect the individual cell groups against abnormal electrical and temperature conditions.
2. 19S LiFePO₄ Battery Voltage
A LiFePO₄ cell has a nominal voltage of approximately 3.2V.
Nominal Pack Voltage
19 × 3.2V = 60.8V
This makes the BMS suitable for a 60V-class LiFePO₄ battery system.
Typical Full-Charge Voltage
19 × 3.65V = 69.35V
The actual charger voltage should always follow the recommended charging specification of the cells used in the battery pack.
3. Main Specifications
- Brand: DALY
- Chemistry: LiFePO₄ / LFP
- Series Configuration: 19S
- Nominal Cell Voltage: Approx. 3.2V
- Nominal Pack Voltage: Approx. 60.8V
- Typical Maximum Pack Voltage: Approx. 69.35V
- Charge Current: 60A
- Discharge Current: 60A
- Port Configuration: Common Port / Same Port
- Temperature Monitoring: NTC
- Balancing: Built-in cell balancing
- High-Current Terminals: B- and P-
- Application Class: 60V LiFePO₄ battery packs
4. 60A Charge & Discharge Capability
The product label specifies:
- Discharge Current: 60A
- Charge Current: 60A
This makes the BMS suitable for medium- to high-current LiFePO₄ battery applications.
The overall current capability of the finished battery pack also depends on:
- Cell current rating
- Busbars
- Battery cables
- Connectors
- Fuse rating
- Battery terminals
- Motor controller or inverter demand
The BMS rating alone should not be used to determine the maximum safe current of the complete battery pack.
5. Common-Port / Same-Port Design
The BMS uses B- and P- terminals.
B-
B- connects to the main negative terminal of the battery pack.
P-
P- is the BMS-controlled negative path used for the external charger and load.
This common-port arrangement simplifies battery-pack wiring by controlling both charging and discharging through the same main BMS output path.
6. Individual Cell Monitoring
The BMS monitors the individual series groups in the 19S battery pack.
This helps detect situations such as:
- One cell group charging too high
- One series group discharging too low
- Excessive voltage difference between cells
- Weak cell groups limiting usable battery capacity
Individual cell monitoring is essential for reliable operation of a multi-series LiFePO₄ battery.
7. Built-in Cell Balancing
The DALY BMS incorporates cell-balancing functionality to help reduce voltage differences between the 19 series groups.
Balancing helps:
- Maintain better cell-voltage consistency
- Reduce premature charge cutoff
- Improve usable battery capacity
- Maintain better pack stability
- Support longer battery service life
Cells should still be properly matched and balanced during initial battery-pack assembly.
8. NTC Temperature Sensor
The BMS includes an NTC temperature sensor.
Temperature monitoring helps protect the battery and BMS against excessive operating temperatures.
Correct NTC placement is particularly important in:
- Electric vehicle batteries
- High-current packs
- Inverter batteries
- Enclosed battery systems
- Solar energy-storage batteries
The temperature probe should be positioned where it can accurately monitor pack temperature.
9. Battery Protection Functions
The DALY BMS is designed to provide essential battery protection including:
- Cell over-voltage protection
- Cell under-voltage protection
- Charge over-current protection
- Discharge over-current protection
- Short-circuit protection
- Temperature protection
- Individual cell monitoring
- Cell balancing
These protections help isolate the battery from unsafe operating conditions.
10. Suitable Applications
The DALY 19S 60A LiFePO₄ BMS is suitable for compatible battery packs used in:
- Electric scooters
- Electric motorcycles
- Electric three-wheelers
- Light electric vehicles
- Solar energy-storage systems
- Home inverter batteries
- UPS systems
- Robotics
- AGVs
- Industrial equipment
- Custom LiFePO₄ battery packs
11. Ideal for 60V-Class LiFePO₄ Batteries
A 19S LiFePO₄ battery operates at approximately:
- 60.8V nominal
- 69.35V at 3.65V per cell
This makes 19S a suitable configuration for many 60V-class LFP battery applications.
It should not be confused with a 60V NMC battery because NMC and LiFePO₄ systems use different cell counts and voltage limits.
12. Compatibility Check Before Ordering
Before purchasing, confirm:
- Battery chemistry is LiFePO₄ / LFP
- Battery configuration is exactly 19S
- Nominal battery voltage is approximately 60.8V
- Charger is suitable for a 19S LiFePO₄ pack
- Required charge/discharge current is within 60A
- Balance-wire configuration matches your battery pack
- B- and P- wiring suits your battery design
Do not select a BMS only by the advertised “60V” rating.
Battery chemistry, number of series cells and current rating must all match.
13. Installation Guidelines
Before connecting the BMS:
- Measure all 19 cell-group voltages
- Verify the balance-wire sequence
- Check voltages progressively through the sense wires
- Connect B- correctly to battery negative
- Connect P- according to the battery wiring design
- Position the NTC sensor correctly
- Use properly rated cables and terminals
- Insulate all exposed high-current connections
- Secure the BMS against vibration and movement
Do not connect the balance harness until the complete wiring order has been verified.
Incorrect balance-wire sequencing can damage the BMS.
14. Important Safety Note
Do not:
- Use this BMS with NMC cells
- Use with an incorrect series configuration
- Reverse battery polarity
- Connect balance wires incorrectly
- Exceed the 60A current rating
- Short the B- or P- terminals
- Operate with damaged cells or wiring
- Install where moisture or conductive debris can reach the connections
Professional installation is recommended for high-capacity lithium battery packs.